www.automationdirect.com/proximity
Proximity Sensors
19
Book 2 (14.1)
Prices as of April 16, 2014. Check Web site for most current prices.
Company
Information
Drives
Soft Starters
Motors
Power
Transmission
Motion: Servos
and Steppers
Motor Controls
Sensors:
Proximity
Sensors:
Photoelectric
Sensors:
Limit Switches
Sensors:
Encoders
Sensors:
Current
Sensors:
Pressure
Sensors:
Temperature
Sensors:
Level
Sensors:
Flow Switches
Pushbuttons
and Lights
Stacklights
Signal
Devices
Process
Relays and
Timers
Pneumatics:
Air Prep
Pneumatics:
Directional Control
Valves
Pneumatics:
Cylinders
Pneumatics:
Tubing
Pneumatics:
Air Fittings
Appendix
Book 2
Terms and
Conditions
AM Series Specifications
Mounting Type
Standard Distance Models Extended Distance Models Triple Distance Models
Shielded Unshielded Shielded Unshielded Shielded
Nominal Sensing Distance
2 mm (0.079 in) 4 mm (0.157 in) 4 mm (0.157 in) 8 mm (0.315 in) 6 mm (0.236 in)
Operating Distance
N/A
Material Correction Factors
See Material Influence table #1 later in this section See Material Influence table #2 later in this section
Output Type
NPN or PNP/N.O. only/3-wire
Operating Voltage
10 to 30 VDC
No-load Supply Current
m20mA m10mA
Operating (Load) Current
3-wire: m200mA / 2-wire: 3-100mA 3-wire: m200mA / 2-wire: 3-100mA m200mA
Off-state (Leakage) Current
3-wire: m10µA / 2-wire: m0.8mA 3-wire: m120µA / 2-wire: m0.8mA m100µA
Voltage Drop
3-wire:1.2 volts max. / 2-wire: 2.8 volts max. m2.0 V
Switching Frequency
3-wire: 2kHz / 2 wire: 1.5 kHz 3-wire: 2kHz / 2 wire: 1 kHz 800 Hz
Differential Travel (% of Nominal Distance)
2 to 10% 1 to 20
Repeat Accuracy
m2% m5%
Ripple
m10% m20%
Time Delay Before Availability (tv)
3-wire: 100ms / 2 wire: 50ms 100 ms
Reverse Polarity Protection
Yes
Short-Circuit Protection
Yes (switch auto-resets after overload is removed)
Operating Temperature
-25° to +70°C (-13° to 158°F)
Protection Degree (DIN 40050)
IEC IP67
Indication/Switch Status
Yellow (output energized)
Housing Material
Nickel-plated brass Chrome-plated brass
Sensing Face Material
Polybutylene Terephthalate (PBT)
Shock/Vibration
See terminology section
Tightening Torque
10 Nm (7.37 lb-ft)
Weight (cable/M12 connector)
70 g (2.47 oz)/30 g (1.06 oz) 96 g (3.39 oz)/34 g (1.2 oz)
Connection
2 meter PVC axial cable / M12 connector
Agency Approvals
N/A UL file E328811
Sink/Source Output
NPN Output
PNP Output
Sink/Source Output
Diagram 1
Diagram 2
Wiring diagrams
AM Series Inductive Proximity Sensors
Wiring diagram when sensor is wired in
sinking mode used with a sourcing module.
Wiring diagram when sensor is wired in
sourcing mode used with a sinking module.
Note: Negative (-) lead is Black on M12 quick
disconnect cables and Blue on axial cables.
Connector